Variable Frequency Drives

AID MobileDuty 100 hp — 460 V Mobile VFD Package

An enclosed mobile variable-frequency drive package for pump speed control. This 100-hp configuration combines a Fuji chassis with AID controls, a NEMA 3R enclosure, input reactor, surge protection and filtered cooling. The structural steel transport cage is an available option.

Specs & manuals ↓
Back to Fluid Solutions

Estimated equipment rental only. Delivery, taxes and applicable fees quoted separately. Final pricing confirmed with dispatch.

Specifications

Equipment

Manufacturer
Advanced Industrial Devices (AID)
Model
MobileDuty MDM10043BAAL0UA

Selected mobile package

Package BOM
MDM10043BAAL0UA
Package manufacturer
Advanced Industrial Devices (AID)
VFD chassis
Fuji FRN0100G1s-4U
Rated motor power
100 hp
Chassis rated current
150 A at 1,000 m without derating
Supply
460 V, 3-phase, 60 Hz; +10% / −15% voltage tolerance
Enclosure
NEMA 3R; powder-coated carbon steel
Enclosure dimensions
60 × 36 × 16 in
Cooling
Air-cooled filter fans with replaceable filters
Ambient range
−20°F (−28°C) to 122°F (50°C)
Humidity
Non-condensing; 95% maximum

Power and controls

Circuit breaker
200 A; 35 kAIC minimum
Disconnect
Rotary lockable circuit-breaker disconnect
Input reactor
5% line-side reactor
Surge protection
UL 1449 device; 40 kA surge current
Control transformer
500 VA
Enclosure heater
200 W
Display
5.7-in OptiPump MD controller and VFD keypad
Control selection
Hand-Off-Auto, speed potentiometer and 4–20 mA
Overload
120% for one minute
Output frequency
0.01–400 Hz
Analog inputs
Two 0–10 VDC and one 4–20 mA
Analog outputs
Two 4–20 mA or 0–10 V
Digital I/O
Seven inputs; two relay and four transistor outputs
Communications
RS-485 Modbus RTU

Options and qualifications

Optional mounting cage
Powder-coated structural steel; nominal 84 × 57 × 48 in
Chassis standards
UL, cUL and CE listed, as stated for the Fuji chassis
Package listing option
UL 508A listed package is an available option; not asserted as standard
Factory sheet
Version 1.3, May 2025; June 2025 reference drawing

Equipment Details

Capabilities & Features

  • Hand-Off-Auto and a speed potentiometer support local pump control.
  • An OptiPump MD controller provides a dedicated operator interface.
  • A line reactor, surge device and filtered fans are integrated into the enclosure.

Available Options

  • Structural steel mounting cage
  • Ethernet expansion
  • DriveLynx remote monitoring
  • Customer-specified digital/analog bulkhead connections
  • UL 508A listed package option