Diesel Centrifugal High Head Pumps

Atlas Copco PAC H43C KD 74HP FT4 — 4 × 3-in Diesel High-Head Pump

A 4-by-3-inch diesel centrifugal pump for high-head dewatering and water transfer. The 74-hp Kohler engine drives a semi-open impeller that passes solids up to 0.75 inches. This selection uses an open-frame arrangement.

Specs & manuals ↓
Back to Fluid Solutions

Estimated equipment rental only. Delivery, taxes and applicable fees quoted separately. Final pricing confirmed with dispatch.

Specifications

Equipment

Manufacturer
Atlas Copco
Model
PAC H43C KD 74HP FT4 — 2020-11 Rev.0B

Selected diesel configuration

Model
PAC H43C KD 74HP FT4
Factory reference
2020-11 Rev.0B
Engine
Kohler KDI 2504TCR
Manufacturer engine rating
74 hp
Engine type
Turbo common-rail diesel, liquid-cooled with radiator
Maximum operating speed
2,600 rpm
Engine emissions
EPA Tier 4 Final
Starting / electrical
Electric start / 12 V
Enclosure
Open-frame package

Pump performance

Suction / discharge
4 in / 3 in flanged
Maximum capacity
660 US gal/min
Maximum head
302 ft
Rating relationship
Maximum flow and head are separate factory curve limits
Impeller
12-in semi-open 4-vane
Maximum solids
0.75 in
Curve test
Clean water; UNI EN ISO 9906 level 2; priming-system and check-valve losses excluded

Priming and materials

Vacuum pump
Diaphragm
Nominal air removal
29.4 cfm
Maximum vacuum
−26.6 inHg
Vacuum-pump drive
Link belt
Casing
ASTM A536 80-55-06 ductile iron
Impeller material
ASTM A536 80-55-06 ductile iron
Shaft
SAF 2205 stainless steel
Mechanical seal faces
Silicon carbide / silicon carbide
Elastomers
VITON
Check valve
ASTM A536 ductile iron with NBR flap
Separator
Aluminum alloy
Wear plate
ASTM A48 Class 20 grey iron
Lubrication
Oil

Fuel, controls and handling

Fuel capacity
60 US gal
Controller
PW 1000
Operating modes
Manual or automatic start-stop with transducers or floats
Frame
ASTM A36 steel; epoxy powder coating
Handling and service
Lifting beam and hinged pump access
Dry package weight
3,215 lb
Wet package weight
3,665 lb

Equipment Details

Capabilities & Features

  • Automatic vacuum priming removes air from the suction line.
  • Float or transducer control supports automatic start-stop operation.
  • A hinged access arrangement supports pump maintenance.
Become Operational

Need this on a mission profile?

We scope, qualify and deploy the right fleet — managed end to end, tracked on GC.