The Heat Wagon HVF410HD is an indirect-fired liquid-fuel heater with two firing rates. The manual lists 412,000 or 272,000 BTU/h input and 354,000 or 231,000 BTU/h delivered heat output, with 3,250 cfm airflow. It runs on winter-blend #2 diesel or #1 kerosene and includes a 57-gallon fuel tank. A high/low firing switch, fan-only setting and thermostat connection support controlled ducted heating. The published electrical requirement is 120 volts, single-phase, at 20 amps.
Estimated equipment rental only. Delivery, taxes and applicable fees quoted separately. Final pricing confirmed with dispatch.
We scope, qualify and deploy the right fleet — managed end to end, tracked on GC.