Direct Fired Heaters

Mr. Heater MH125QFAV — Propane Forced-Air Heater

The Mr. Heater MH125QFAV is a portable propane construction heater with variable heat input from 75,000 to 125,000 BTU/h. Its direct-fired fan sends heated combustion air into the work area, with Quiet Burner Technology, automatic spark ignition and a manual gas control. A 10-foot hose and regulator are included. The heater uses an electrical fan, has a high-temperature limit control, and operates without a thermostat or ductwork. The compact body measures 21.25 by 11.75 by 16 inches in the manufacturer’s 2018 manual.

Specs & manuals ↓
Back to HVAC

Estimated equipment rental only. Delivery, taxes and applicable fees quoted separately. Final pricing confirmed with dispatch.

Specifications

Equipment

Manufacturer
Mr. Heater
Model
MH125QFAV

Equipment specifications

Heat input, variable
75,000–125,000 BTU/h
Fuel
Propane only; vapor withdrawal
Heater type
Direct-fired, forced-air construction heater
Electrical supply, 2018 manual
115 V, single-phase, 60 Hz
Electrical input, 2018 manual
2 A / 230 W
Minimum operating voltage
100 V
Propane consumption
3.5–5.8 lb/h
Minimum supply pressure to regulator
20 psi
Maximum supply pressure
Propane bottle pressure
Regulator outlet pressure
20 psi
Ignition
Automatic spark; manual gas valve
High-temperature control
240°F
Included hose length
10 ft; regulator included
Thermostat
Not usable with this model
Length × width × height, 2018 manual
21.25 × 11.75 × 16 in
Weight, current manufacturer specification
21.9 lb
Duct connection
Not for use with ductwork
Ventilation openings, manual
2 sq ft near floor and 2 sq ft near ceiling
Combustible clearance, outlet / top
6 ft / 6 ft
Combustible clearance, sides / floor
2 ft / 0 ft
Application
Temporary heating of buildings under construction, alteration or repair

Equipment Details

Capabilities & Features

  • Variable heat setting
  • Quiet Burner Technology
  • Automatic spark ignition
  • High-temperature limit switch
  • Thermoelectric safety valve
  • 10-ft hose and regulator included
  • Portable carry handle
Become Operational