Hydronic Surface Heaters

Wacker Neuson E 3000 — 385,000-BTU/h Hydronic Surface Heater

The Wacker Neuson E 3000 circulates heated fluid through 3,000 feet of hose for ground thawing, concrete curing and frost prevention. The 2013 manufacturer specification lists 385,000 BTU/h of heat output, a 230-gallon diesel tank and two fluid-circulation pumps. This detail set uses the manufacturer’s 0620679 configuration with generator and lifting bail; accessory heat exchangers extend the system to temporary air heating.

Specs & manuals ↓
Back to HVAC

Estimated equipment rental only. Delivery, taxes and applicable fees quoted separately. Final pricing confirmed with dispatch.

Specifications

Equipment

Manufacturer
Wacker Neuson
Model
E 3000 (0620679)

Equipment specifications

Manufacturer configuration reference
E 3000, item 0620679 — generator and lifting bail
Heat output, 2013 manual
385,000 BTU/h / 113 kW
Heater efficiency
83%
Burner fuel
Diesel
Heat delivery
Circulating hydronic heat-transfer fluid
Hose length
3,000 ft / 914 m
Heat-transfer-fluid capacity
115 US gal / 435 L
HTF pump flow
Two pumps, each 265 US gal/h / 1,003 L/h
Working hose pressure
90–110 psi / 6.2–7.5 bar
Fuel tank capacity
230 US gal / 871 L
Maximum published runtime
Up to 140 h
Standard ground-thaw area
3,000–6,000 sq ft
Accelerated ground-thaw area
6,000 sq ft
Standard concrete-curing area
6,000 sq ft
Expanded concrete-curing area
18,000 sq ft
Frost-prevention area
9,000 sq ft
Air-heating volume, with accessories
525,000 cu ft
Weight without fuel, item 0620679
7,073 lb / 3,209 kg
Weight with full fuel, item 0620679
8,582 lb / 3,893 kg
Overall length
181 in / 459 cm
Overall width
91 in / 231 cm
Overall height
94 in / 238 cm
Gross vehicle weight rating, item 0620679
8,582 lb / 3,895 kg
Gross axle weight rating, item 0620679
5,200 lb / 2,359 kg
Wheels / tires, item 0620679
15 in / 215 75R15
Trailer brakes
Electric
Maximum published towing speed
45 mph / 72 km/h
Burner nozzle
2.25 US gal/h × 80° B
Burner fuel pressure
150 psi / 10.34 bar

Equipment Details

Capabilities & Features

  • Hydronic ground thawing
  • Concrete curing
  • Frost prevention
  • Dual fluid-circulation pumps
  • Generator and lifting-bail reference configuration
  • Accessory air-heating capability

Available Options

  • Accessory hydronic-to-air heat exchangers
  • Expanded concrete-curing layout

More in Hydronic Surface Heaters

View all →
Become Operational

Need this on a mission profile?

We scope, qualify and deploy the right fleet — managed end to end, tracked on GC.