Indirect Fired Heaters

Wacker Neuson HI400HD G — Indirect-Fired Heater

The Wacker Neuson HI400HD G is a vented indirect-fired heater with a selector for natural gas or propane. Its factory manual lists separate heat ratings: 380,548 BTU/h gross input and 329,174 BTU/h net output on natural gas, or 334,700 BTU/h gross input and 289,515 BTU/h net output on LP. The Revision11 configuration moves 3,015 cfm and uses a 120-volt, 60-Hz supply. The actual gas-specific ratings replace an undifferentiated 400K class label.

Specs & manuals ↓
Back to HVAC

Estimated equipment rental only. Delivery, taxes and applicable fees quoted separately. Final pricing confirmed with dispatch.

Specifications

Equipment

Manufacturer
Wacker Neuson
Model
HI400HD G

Equipment specifications

Gross heat input, natural gas
380,548 BTU/h
Gross heat input, propane
334,700 BTU/h
Net heat output, natural gas
329,174 BTU/h
Net heat output, propane
289,515 BTU/h
Airflow, Revision11 manual
3,015 cfm
Fuel
Natural gas or LP
Electrical supply
120 VAC, 60 Hz
Operating current at 15°C
11.8 A
Weight without fuel
497 lb
Dimensions, L × W × H
84 × 33 × 43.5 in
Noise level at 1 m
74 dB(A)
Natural-gas consumption
355.97 cu ft/h
Propane consumption
3.65 US gal/h
Flue diameter
6 in
Natural-gas supply-pressure range
7–10 in water column
LP supply-pressure range
8–13 in water column
Burner pressure, NG / LP
6.40 / 6.52 in water column
Static air-pressure limit
0.60 in water column
Fuel switching
Gas selector valve
Heating method
Vented indirect-fired air heater
Controls
On/off mode switch; operating status/reset; remote thermostat connection

Equipment Details

Capabilities & Features

  • NG/LP gas selector
  • Vented indirect-fired heat
  • Remote thermostat connection
  • Operating-status/reset control

Available Options

  • Supply duct adapters
  • Remote thermostat
  • Venting components