Diesel Generators

AIRMAN SDG220S-8E1 — 176 kW Prime Diesel Generator

The SDG220S-8E1 supplies 176 kW of three-phase prime power for temporary industrial loads. Its sound-attenuated steel enclosure combines a digital DSE controller, selectable output voltages and 285 gal fuel storage. External fuel connections, service access and 110% fluid containment support extended site operation; unit and trailer dimensions are listed separately.

Specs & manuals ↓
Back to Power Solutions

Estimated equipment rental only. Delivery, taxes and applicable fees quoted separately. Final pricing confirmed with dispatch.

Specifications

Equipment

Manufacturer
AIRMAN
Model
SDG220S-8E1

Equipment specifications

Three-phase prime output
176 kW / 220 kVA
Three-phase standby output
194 kW / 242 kVA
Frequency
60 Hz
Fuel
Ultra-low-sulfur diesel
Engine
John Deere 6068
Fuel tank capacity
285 gal
Three-phase voltage selection
208 /220 /240 /416 /440 /480 V
Current at 208 V, three phase
608 A
Current at 240 V, three phase
529 A
Current at 480 V, three phase
264 A
Three-phase power factor
0.8
Alternator
Stamford
Excitation
Brushless with AVR
Number of poles
4
Voltage regulation
±0.5%
Frequency regulation, steady state
±0.25% of overall mean
Controller
DSE 7310 MKII
Engine speed
1,800 rpm
Engine cylinders
6
Engine displacement
415 in³
Engine rated output at 1,800 rpm
295 BHP
SAE gross output at 1,800 rpm
323 BHP
Governor
Electronic
Engine emissions
Tier 4 Final
Aftertreatment
DEF; DOC; SCR; ASC
Fuel consumption at full /75% /50% load
12.1 / 9.5 / 6.8 gal/h
Runtime at full load
23.5 h
Engine lubricating-oil capacity
8.7 gal
Coolant capacity
7.1 gal
Sound at 23 ft, no-load /full-load
63 / 69 dB(A)
Unit dry weight
7,452 lb
Unit operating weight
9,656 lb
Trailer weight
1,365 lb
Operating weight with trailer
11,021 lb
Unit dimensions (L × W × H)
137.8 × 51.2 × 87.4 in
Trailer dimensions with generator (L × W × H)
219 × 83.75 × 103.4 in
Fluid containment
110%
Enclosure
Powder-coated 16-gauge steel
Door hinges and service hardware
Stainless steel
Fuel connection
External tank connection with selector valve
Cooling
Liquid/air fin-and-tube radiator; 50/50 coolant mix
240 V single-phase prime output
117.9 kW
240 V single-phase standby output
129.9 kW
Single-phase selectable voltages
120 /127 /139 /240 /254 /277 V
DEF tank capacity
11.7 gal
Maximum DEF consumption
1 gal per 5.7 gal diesel
DEF runtime at full load
46 h

Equipment Details

Capabilities & Features

  • DSE digital controls and electrical protection
  • Selectable three-phase output voltages
  • 110% fluid containment and external fuel connection
  • Sound-attenuated enclosure with lockable access

Available Options

  • SmartLoad automatic load optimization
  • Cam-lock output connections
  • Cold-weather equipment
Become Operational

Need this on a mission profile?

We scope, qualify and deploy the right fleet — managed end to end, tracked on GC.